dotAutomatic Reclosing Device for ELB (ARELB) ?
ARELB acts reclosing a circuit breaker automatically to improve the electrical service continuity after a momentary trip of ELB (earth leakage breaker). To reduce probability of hazard to personal and equipments, and to reduce time loss, ARELB has electronic intelligences to distinguish the trip has been caused by momentarily fault or not, and try to check the line state safe or not, even if the breaker has been closed again. And also to check after certain fault and reclosing, ARELB has a memory system to record the history of trip, check and reclose, as like a black box.
dotProspected Merits
educe manpower and maintenance expense
Conformation of safety before reclosing ELB
Steady supply of electricity to remote and no personnel working inside sites
Maximize the Equipment operation efficiency
Satisfy for the customer service requirement
dot1. Specifications
Description |
MODEL |
GMT-ARE 20 |
GMT-ARE 30 |
GMT-ARE 50/75 |
---|---|---|---|---|
Reclosing action |
MOTOR |
DC GEARED MOTOR | DC GEARED MOTOR | DC GEARED MOTOR |
ARM |
Straight Arm | Straight Arm | Straight Arm | |
Direction of Rotor |
CCW | CCW | CCW | |
Power Usage |
Commercial electrical |
AC 220V, 60Hz | AC 220V, 60Hz | AC 220V, 60Hz |
Dimension |
Unit (mm) |
W75×H75×D120 | W75×H75×D120 | W85×H85×D120 |
Communication Method |
Data in/out |
UART (RS-232C) | UART (RS-232C) | UART (RS-232C) |
Available Information |
Event of Recovery stored in memory |
30 times | 30 times | 30 times |
Earth Leakage Breaker |
Rated Breaking Current |
20A | 30A | 50/75A |
Leakage Break Sensitivity |
30mA | 30mA | 30mA | |
Rated Interrupt Current |
2.5kA | 2.5kA | 5kA | |
Leakage Break Time |
0.03 second | 0.03 second | 0.03 second | |
Non₋trip leakage current |
15mA | 15mA | 15mA |
dotSpecial Features
Black Box inside
With Data stored in internal memory by realtime, at anytime and everywhere, we can prepare counteraction about the reason why the ELB is trip₋down and can find out solutions how to counteract about any trouble quickly!With realtime clock inside
With 30 events of reclosing stored in internal memories by realtime, could study what is happened at that timeSupporting PC View
Can find out the reason of ELB trip down and the way of improve in futureEasy to distinguish operating status
LED indicates operating status
dotOutline drawing for install
dotCertifications
EMC/EMS TEST 합격: EMC 기술센터
EMS 안전인증 합격: 한국전기연구원
ISO 9001:2008 인증 취득
ISO 14001 인증 취득
전기용품 안전인증(KC) 취득: KTL(한국산업기술시험원)
dot제품 기능 업그레이드
2 Digit LED를 통한 누설전류값 표시
PDA 단말기를 통한 프로그램 및 저장 DATA 관리
인터넷망을 통하여 원격지에서 누전차단기의 동작상태를 확인 및 제어기능
ZigBee 무선통신과 CDMA 모뎀을 결합하여 PC나 유지보수자의 핸드폰으로 동작 확인 및 제어기능